filters

Clear the filters
Назад

Show:

ACD-EN
Hochiki ACD-EN
Analogue Addressable Multi-Sensor Detector - Smoke Heat & CO
Hochiki ACD-EN Analogue Addressable Multi-Sensor Detector - Smoke Heat & CO, An addressable loop-powered multi-sensor, with smoke, heat and CO sensing elements. The unit offers 24 different modes of operation*1 and seamlessly matches the other sensors in the ESP Range. The CO sensing element can be used to detect smoke as well as life-threatening CO levels (acting as a CO alarm).
ALN-EN
Hochiki ALN-EN
Photoelectric Smoke Sensor
The ALN-EN incorporates Hochiki’s newest High Performance Chamber Technology removing the need to use Ionisation Smoke Sensors in the majority of applications. This also allows the sensor threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms. • Removable, High Performance chamber • Twin LEDs allow 360� viewing - green when polling, turn red in fire • Locking mechanism (sensor to base) • Variable sensitivity • Electronically addressed • Pulsing/non-pulsing controlled from panel • Approved by LPCB & Vds • SIL Level 2 approved varients available • Available in white
ACC-EN
Hochiki ACC-EN
Multi-Sensor - Photoelectric and Hea
The ACC-EN has 3 modes, which are controlled from the Control Panel, allowing either the optical element or thermal element or both elements to be active in making the fire decision. The sensor polling LEDs can be controlled via the Control Panel (pulsing/non-pulsing). The ACC-E smoke chamber can esily be removed or replaced for easy maintentance. • User selectable modes • Incorporates Optical & Heat elements • Removable, High Performance Chamber • Twin LEDs allow 360 degree viewing - green when polling, turn red in fire • Pulsing/non-pulsing controlled from panel • Variable sensitivity • Electronically Addressed • LPCB & VdS approved to Classes A1 & C • SIL Level 2 approved variants available • Available in white
ACC-EN(WHT)
Hochiki ACC-EN(WHT)
ESP Analogue Addressable Multi-Sensor with thermal element and High Performance photoelectric smoke chamber
ACC-EN(WHT) Hochiki’s ESP Analogue Addressable Multi-Sensor incorporates a thermal element and High Performance photoelectric smoke chamber
ATJ-EN
Hochiki ATJ-EN
Analogue Heat Sensor
The ATJ-EN incorporates a variable temperature heat element and a rate of rise heat element, both of which are controlled from the Control Panel, allowing either thermal element or both elements simultaneously to be active in making the fire decision. The sensor polling LEDs can also be controlled via the Control Panel (pulsing/non-pulsing)*. • User selectable modes • Incorporates Fixed Temperature and Rate of Rise Heat elements • Twin LEDs allow 360 degree viewing - green when polling, turn red in fire • Pulsing/non-pulsing controlled from panel • Electronically addressed • LPCB & VdS approved to Classes A, B & C • SIL Level 2 approved variants available • Available in white
YBN-R/3
Hochiki YBN-R/3
Base
A recessed base adaptor is available allowing sensors to be flush mounted to the ceiling surface. Specification Part No. : YBN-R/3 YBN-R/3 (B
YBO-BSB
Hochiki YBO-BSB
Analogue Addressable Base Sounder Beacon YBO-BSB
Model YBO-BSB is an addressable loop powered Base Sounder with integral Beacon, innovatively designed to give a range of tones and volumes with a maxi
YBO-BS
Hochiki YBO-BS
Analogue Addressable Base Sounder YBO-BS
Model YBO-BS is an addressable loop powered Base Sounder innovatively designed to give a range of tones and volumes with a maximum output of up to 98d
FB1
Hochiki FB1
Beam Detector with Low Level Controller and 5-40m Reflector
The FB-1 (FIREbeam) is a reflective beam Smoke Detector which features advanced motorised technology allowing it to self-align itself to the centre of the reflector when commissioning. Commissioning is a semi-automatic procedure where the unit aligns itself directly onto the centre of the reflector. Once commissioned the detector continually monitors alignment and will automatically realign itself back to the centre of the reflector if any building movement occurs. The detector comes with a separate controller unit which allows engineers to commission, monitor and maintain from ground level. Detection range is 40 m for the standard unit, increasing to 80 m or 100 m with the addition of the medium or long-range reflector kits.
HCP-E
Hochiki HCP-E
Analogue Addressable Manual Call Point HCP-E
Model HCP-E is a Manual Call Point, which is fully compatible with Hochiki’s ESP analogue addressable protocol. The HCP-E incorporates a red LED moun
CHQ-DIM
Hochiki CHQ-DIM
Analogue Dual Input Module CHQ-DIM
Features - Single Loop Address - Loop Powered - 2 Independent Inputs for Monitoring of Volt Free Contacts - Each Input can be Configured to Mo
CHQ-DRC
Hochiki CHQ-DRC
Analogue Dual Relay Controller CHQ-DRC
Features - Loop Powered - Single Address - 2 Independently Controlled Changeover relays - Relays Contact Rated at 30Vdc at 1 amp - Auxiliary